HWAXEE EQUIPMENT
RO Water Purifier Online Testing System | HX-108CDS / HX-108CDSG
Model: HX-108CDSG — Functional Testing
SKU:
$10,500.00 USD
Final pricing may vary based on configuration and project requirements.
Key Functions
Technical Topics
Explore Technical ResourcesEquipment Overview
The HWAXEE HX-108CDS / HX-108CDSG RO Water Purifier Online Testing System is designed for end-of-line inspection of complete RO water purifiers. HX-108CDSG provides functional testing; HX-108CDS combines whole-unit air tightness and functional testing.
HX-108CDSG — Functional Testing
The HX-108CDSG is designed for manufacturers that primarily need to verify whether the RO water purifier is operating correctly before leaving the production line.
It uses air to simulate water-circuit operating conditions for functional inspection, reducing the need for conventional long-duration water testing.
Key Functions
Depending on the RO water purifier configuration, the system can be used to verify key operating functions including:
The testing sequence can be configured according to the structure and control logic of the customer's RO water purifier.
Booster pump
Inlet water solenoid valve
Flush / wastewater solenoid valve
High-pressure switch
Low-pressure switch
Check valve
Water flow
Electrical control logic
TDS / desalination-related performance
Pure water flow
Faster End-of-Line Inspection
The HX-108CDSG is designed for production-line functional inspection, with a test cycle of ≤1 minute per unit under the corresponding test configuration.
Using air to simulate water-circuit conditions can also reduce residual water introduced during functional inspection, simplifying subsequent handling, packaging and shipment.
Technical Specifications
| Parameter | HX-108CDSG — Functional Testing | HX-108CDS — Air Tightness + Functional Testing |
|---|---|---|
| Model | HX-108CDSG | HX-108CDS |
| Test Object | Complete RO Water Purifier | Complete RO Water Purifier |
| Main Testing | Functional Testing | Air Tightness + Functional Testing |
| Testing Method | Air-Simulated Functional Testing | Air + Electrical Testing |
| Air Tightness Testing | — | Yes |
| Functional Testing | Yes | Yes |
| Air Tightness Pressure | — | 0.05–0.8 MPa |
| Air Tightness Accuracy | — | ±0.25% F.S. |
| Functional Pressure | According to Test Item | 0.1–0.3 MPa / 0.1–0.6 MPa |
| Flow Measurement Range | According to Configuration | 1–100 L/min |
| Flow Accuracy | According to Configuration | ±1.5% F.S. |
| Time Setting | Configurable | 1.0–999.9 s |
| Typical Test Cycle | ≤1 min/unit | Approx. 6–7 min/unit |
| Result Judgment | Automatic | Automatic |
| Application | Production-Line Functional Inspection | Comprehensive End-of-Line Inspection |
HX-108CDSG — Functional Testing
The HX-108CDSG is designed for manufacturers that primarily need to verify whether the RO water purifier is operating correctly before leaving the production line.
It uses air to simulate water-circuit operating conditions for functional inspection, reducing the need for conventional long-duration water testing.
Key Functions
Depending on the RO water purifier configuration, the system can be used to verify key operating functions including:
The testing sequence can be configured according to the structure and control logic of the customer's RO water purifier.
Booster pump
Inlet water solenoid valve
Flush / wastewater solenoid valve
High-pressure switch
Low-pressure switch
Check valve
Water flow
Electrical control logic
TDS / desalination-related performance
Pure water flow
Faster End-of-Line Inspection
The HX-108CDSG is designed for production-line functional inspection, with a test cycle of ≤1 minute per unit under the corresponding test configuration.
Using air to simulate water-circuit conditions can also reduce residual water introduced during functional inspection, simplifying subsequent handling, packaging and shipment.
Technical Specifications
| Parameter | Details |
|---|---|
| Model | HX-108CDSG |
| Test Object | Complete RO Water Purifier |
| Main Testing | Functional Testing |
| Testing Method | Air-Simulated Functional Testing |
| Air Tightness Testing | — |
| Functional Testing | Yes |
| Air Tightness Pressure | — |
| Air Tightness Accuracy | — |
| Functional Pressure | According to Test Item |
| Flow Measurement Range | According to Configuration |
| Flow Accuracy | According to Configuration |
| Time Setting | Configurable |
| Typical Test Cycle | ≤1 min/unit |
| Result Judgment | Automatic |
| Application | Production-Line Functional Inspection |
HX-108CDS — Air Tightness + Functional Testing
The HX-108CDS is designed for manufacturers that need both whole-unit sealing inspection and operating-function verification.
Key Functions
Air tightness testing can be performed on:
The system monitors the testing process and automatically displays OK / NG results after the air tightness test.
Water inlet
Pure water outlet
Purified water outlet
Wastewater outlet
Functional Testing
The HX-108CDS can also verify key operating components and functions, including:
- High-pressure switch
- Low-pressure switch
- Flush valve
- Water inlet valve
- Check valve
- Pure water / wastewater flow
- Purified water flow
- Booster pump
- Standby current
Individual testing functions can be selected according to the required product configuration.
Configurable Test Parameters
Different product models can use different preset testing parameters.
For air tightness testing, parameters such as inflation time, stabilization time, test time, exhaust time, allowable pressure drop and test limits can be configured according to the testing requirement.
Technical Specifications
| Parameter | Details |
|---|---|
| Model | HX-108CDS |
| Test Object | Complete RO Water Purifier |
| Main Testing | Air Tightness + Functional Testing |
| Testing Method | Air + Electrical Testing |
| Air Tightness Testing | Yes |
| Functional Testing | Yes |
| Air Tightness Pressure | 0.05–0.8 MPa |
| Air Tightness Accuracy | ±0.25% F.S. |
| Functional Pressure | 0.1–0.3 MPa / 0.1–0.6 MPa |
| Flow Measurement Range | 1–100 L/min |
| Flow Accuracy | ±1.5% F.S. |
| Time Setting | 1.0–999.9 s |
| Typical Test Cycle | Approx. 6–7 min/unit |
| Result Judgment | Automatic |
| Application | Comprehensive End-of-Line Inspection |
Automatic Test Judgment & Data Monitoring
For the HX-108CDS, the system can automatically display OK / NG results after functional testing and show the status of individual tested components.
The system also supports product parameter management and test-data recording.
Product barcodes can be entered manually or through a barcode scanner, while product information and inspection records can be associated with the test process.
The HX-108CDS also supports barcode-based automatic parameter loading and automatic test startup.
Designed for RO Water Purifier Production Lines
These systems are suitable for:
- RO water purifier manufacturers
- Water purifier assembly lines
- Multi-model production
Different RO purifier designs may have different water circuits, components and control logic. HWAXEE can configure the testing process according to the customer's product and production requirements.
Need a Custom Testing Configuration?
Every RO water purifier production line is different.
Send HWAXEE your product model, testing requirements, production capacity and destination country, and we can recommend a suitable testing configuration.
Final specifications and pricing depend on the selected model, test items and customized configuration.
International & Local Testing Requirements: HWAXEE can tailor testing procedures, parameters and equipment configurations to the applicable standards and requirements of your target market, including European, American and Southeast Asian markets. Share your product specifications, destination country and required standard or test method so our engineers can assess a suitable customized solution.
